TSK Powder Technical Center

Home / Technology / High‑efficiency cyclones

ACS

High‑efficiency cyclones

Cyclone systems that recover more product from dryer and process air, and keep dust emissions within limits, on new lines or as a retrofit.

ACS high-efficiency cyclones on a steel structure, seen from below
Advanced Cyclone Systems (ACS)

ACS cyclone systems

ACS is the only company worldwide dedicated exclusively to cyclone systems. Each cyclone is designed with PACyc (Particle Agglomeration in Cyclones), its model for predicting and optimizing collection efficiency. Over 400 installations in 37 countries.

High‑efficiency cyclones for emission control and product recovery: pre‑separators, Hurricane final‑stage families and ReCyclone (3:14)
Hygienic stainless steel ACS cyclone

Powder recovery

Products are separated from the process gas after drying, grinding and mixing in pharmaceuticals, food, chemicals, fertilizers and nanoparticles. ACS cyclones raise product yield and can meet strict emission limits without further filters downstream.

  • Hygienic, GMP‑compliant designs; small units open with a tri‑clamp
  • No filter fibres in the product, no cross‑contamination
  • Fast cleaning and product changeover
  • Wide range of temperature, pressure and moisture
ACS cyclone system on a steel structure

Emission control

Particulate emissions from boilers, incinerators, furnaces, kilns and dryers in energy, ceramics, cement and pellet production. Meet stack limits, protect downstream processes and clean the ambient air.

  • Below 30 mg/Nm³ with Hurricane cyclones, comparable to ESPs
  • 5–25 mg/Nm³ with ReCyclone EH
  • No temperature limit with suitable metals or refractories
  • No moving parts, low maintenance

Efficiency against cost of ownership

Chart: collection efficiency against total cost of ownership. ACS cyclone systems sit above multicyclones in efficiency and below ESPs, bag filters and wet venturi scrubbers in maintenance and operating cost
Source: Advanced Cyclone Systems

Conventional cyclones are cheap to run but let fines through. Bag filters, ESPs and wet scrubbers reach low emissions, at the cost of filter media, high‑voltage power, water treatment or higher investment.

ACS cyclones close most of that gap in efficiency while keeping the running cost of a cyclone. Where the limit allows, they replace the filter; where it does not, they cut the load on it.

  • No filter media to replace, no water to treat
  • Lower investment than an ESP
  • Lower maintenance and operating cost than a bag filter

Products and technologies

ACS Hurricane cyclone: air and particles enter tangentially, collected particles leave through the rotary valve, cleaned air exits at the top

Hurricane cyclones

Cyclone families for each application

Families optimized by numerical simulation, from compact pre‑separators to final‑stage collectors.

  • SD, DX, AT: pre‑separators, low cost and pressure drop
  • TX, HR, RX, RE, EX, MK: final‑stage families for fine particles
  • Emissions down to below 30 mg/Nm³
ReCyclone MH system: a mechanical recirculator after the Hurricane cyclone returns uncaptured fines to the cyclone inlet through a venturi or fan

ReCyclone MH System

Mechanical recirculation, patented

A recirculator downstream returns uncaptured fine particles to the Hurricane cyclones.

  • Emissions reduced by 30–60%, to 15–45 mg/Nm³
  • Pressure drop 150–200 mm w.g.
  • Robust, no temperature limit, low investment
ReCyclone EH system: an electrified recirculator after the Hurricane cyclone returns very fine particles to the cyclone inlet

ReCyclone EH System

Electrostatic recirculation

DC high voltage on the recirculator returns very fine particles, including the 1–5 µm range, to the cyclones.

  • Emissions reduced by 40–70%, to 5–25 mg/Nm³
  • Up to 400 °C; pressure drop 120–170 mm w.g.
  • Power only 10–15% of an ESP

Diagrams courtesy of Advanced Cyclone Systems. Figures from ACS specifications published by PRECI.

How the technology works

01

Numerically optimized geometry

Each Hurricane geometry is the solution of an optimization problem, developed by ACS with the Faculty of Engineering of the University of Porto. The geometry is set for the application: maximum collection, minimum re‑entrainment, at an agreed pressure drop.

  • Captures powders with a volume median diameter below 5 µm
  • Higher efficiency than other cyclones at the same pressure drop
  • Patented geometries

02

PACyc design model

ACS sizes every system with PACyc (Particle Agglomeration in Cyclones), its model of how fine particles cluster inside the cyclone. Conventional cyclone models ignore agglomeration and under‑predict collection of fines.

  • Published in Chemical Engineering Journal 162 (2010) 861–876
  • Predicts grade efficiency for the actual powder and load
  • API spray dryer, 5.5 µm median: 97.2% predicted, 96–98% measured

03

Recirculation of fines

In a ReCyclone system, the fines that pass the cyclone are concentrated in a recirculator and returned to the cyclone inlet. There they agglomerate with coarser incoming particles and are collected.

  • MH: mechanical recirculator, no temperature limit
  • EH: fines are charged by a DC field; no collecting plates, so dust resistivity does not matter
  • EH high‑voltage power is 10–15% of an ESP

Reference installations

ACS systems in operation. Each system is sized for the plant’s own particle size, load and emission limit.

Emission control

Biomass boiler, Hurricane battery before the stack
Biomass boiler, Hurricane battery before the stack
Biomass boiler, cyclone battery and stack
Biomass boiler, cyclone battery and stack
Biomass and coal boiler, cyclone batteries
Biomass and coal boiler, cyclone batteries
Biomass dryer, Hurricane cyclones on a steel structure
Biomass dryer, Hurricane cyclones on a steel structure

Product recovery

Pharmaceutical ingredients, hygienic cyclone in a cleanroom
Pharmaceutical ingredients, hygienic cyclone in a cleanroom
Chemicals, product recovery battery
Chemicals, product recovery battery
Food ingredients, twin hygienic cyclones
Food ingredients, twin hygienic cyclones
Mineral processing, cyclones ahead of a silo
Mineral processing, cyclones ahead of a silo

Photos courtesy of Advanced Cyclone Systems.

What we need to design a system

ACS guarantees an outlet emission or a collection efficiency for the specific powder. The design starts from measured data, not from a catalogue size.

Particle size distribution

Laser‑sized from an isokinetic sample at the stack or cyclone outlet

Gas flow and temperature

Actual and normal flow rate, operating temperature, moisture

Inlet concentration

Dust or product load into the cyclone, in g/Nm³

Particle density

True density of the powder or fly ash

Target

Emission limit in mg/Nm³ or required product yield

Allowable pressure drop

Available fan margin, in kPa or mm w.g.

Questions and answers

Questions engineers ask about cyclones

Where do high‑efficiency cyclones fit in a plant?

After spray dryers, mills and coolers to recover product, and as final dedusting before the stack on dryers, boilers and kilns.

Can a cyclone system meet the emission limit on its own?

In many applications ACS systems reach emissions below 30 mg/Nm³, comparable to electrostatic precipitators, with no filter media to replace. The result depends on the particle size and the dust load, so it is confirmed by measurement.

Can they be fitted to an existing plant?

Yes. ACS cyclones are retrofitted on existing dryers, mills, boilers and kilns, often in the space of the cyclones they replace.

What does a dust and recovery survey measure?

The dust load and the product lost at the exhaust. From those figures the retrofit is sized and costed, with the value of the product recovered.

Measure the losses on your plant

A dust and recovery survey shows what a retrofit returns before you invest.

Request a dust and recovery survey

ACS applications

Product recovery and emission control results from dryers, mills and boilers.

View applications →
ACS

Advanced Cyclone Systems, S.A.

High‑efficiency cyclone technology. TSK is ACS's exclusive partner in Thailand.

ACS official site ↗

Contact our engineers

+66 81 978 8389 · contact@tskengineering.co.th

Talk to an engineer