The problem
A bag filter after the dryer had operating problems from the humid exhaust. In 2001 ACS replaced it with a ReCyclone MH, which met the limit of the time (150 mg/Nm³) with no filter maintenance. In 2016 Bondalti needed a solution for a stricter limit.
The solution
ACS installed six Hurricane MK ø900 mm agglomerator cyclones in parallel, with a common hopper, rotary valve and inspection doors, in stainless steel AISI 304 with heat tracing and insulation against condensation. The new design needs no recirculation.



| Powder | Sulfanilic acid fines |
|---|---|
| Actual flow rate | 6 700–12 000 m³/h |
| Temperature | 107–115 °C |
| Inlet concentration | 31 567 mg/Nm³ |
Result
Official reports confirm emissions of 34.5–44.7 mg/Nm³, consistently under 40 mg/Nm³. Fine product escaping the process cyclone is returned to the end product, losses fell by more than 70%, and the system is easier to clean and maintain.
| Guaranteed emissions | 100 mg/Nm³ |
|---|---|
| Expected efficiency | 99.86–99.92 % |
| Verified emissions | 34.5–44.7 mg/Nm³ |
| Cut in powder losses | > 70 % |
Source: Advanced Cyclone Systems (ACS) case study. Figures and photos: ACS.