The problem
Each milling line had a process cyclone with its own fan on top, which caused vibration and maintenance problems. Exhaust air went to a shared settling chamber, where about 100 kg of paprika a week was lost to cross‑contamination. The chamber was hard to reach, so losses were often noticed hours late.
The solution
The process cyclones were kept, but their fans and the settling chamber were removed. A battery of four Hurricane HR ø750 mm cyclones now treats all three lines at once, with a common hopper, rotary valve and inspection doors, in stainless steel AISI 304 with food‑grade finish. A new ID fan with variable speed drive and a stack complete the line.
| Powder | Paprika |
|---|---|
| Actual flow rate | 11 010 m³/h |
| Temperature | 48 °C |
| Inlet concentration | 272 mg/Nm³ |
Result
The system recovers the losses of the process cyclones in normal operation and when they clog, with clean air at the stack. It also gives operating savings from fewer fans and less maintenance.
| Expected separation efficiency | 97.4–97.9 % |
|---|---|
| Expected emissions | 6 mg/Nm³ |
| Guaranteed emissions | 30 mg/Nm³ |
| Expected pressure drop | 1.4 kPa |
Source: Advanced Cyclone Systems (ACS) case study. Figures and photos: ACS.