The problem
The existing cyclones after the spray dryer emitted about 170 mg/Nm³, above the limit, and valuable milk powder was lost to the atmosphere. The target was under 75 mg/Nm³.
The solution
ACS took an isokinetic dust sample at the stack and measured the particle size distribution. It then designed eight Hurricane HR ø850 mm cyclones in two batteries in parallel, guaranteeing under 75 mg/Nm³ (expected under 50) at 1.7 kPa.




| Powder | Milk powder |
|---|---|
| Normalized flow rate (dry) | 21 150 Nm³/h |
| Temperature | 70–80 °C |
| Inlet concentration | 245 mg/Nm³ |
Result
Verified emissions are 25 mg/Nm³. The system meets future limits with lower investment, maintenance and operating costs than a bag filter.
| Emissions before | ≈ 170 mg/Nm³ |
|---|---|
| Guaranteed emissions | 75 mg/Nm³ |
| Verified emissions | 25 mg/Nm³ |
| Expected pressure drop | 1.7 kPa |
Source: Advanced Cyclone Systems (ACS) case study. Figures and photos: ACS.