The problem
During filling, powder escaped the bags into the dedusting system: about 120 kg per line and 600 kg per day across five lines. The mixed powder could not be reused.
The solution
Each filling machine received a Hurricane AT system of two ø530 mm cyclones with a discharge hopper and container. The air then passes a cartridge filter before release. CIP nozzles allow cleaning between juice flavours.



| Powder | Soluble juice powder |
|---|---|
| Actual flow rate | 3 857 m³/h per line |
| Temperature | 30 °C |
| Expected pressure drop | 1.47 kPa |
Result
Losses dropped from 600 kg to 7 kg per day, about 200 t of product recovered a year, and the plant now meets emission regulations. Filter maintenance and filling‑line downtime also fell, despite tight space restrictions on site.
| Losses before | 600 kg/day (5 lines) |
|---|---|
| Losses after | 7 kg/day |
| Loss reduction | ≈ 99 % |
| Recovered product | ≈ 200 t/year |
| Guaranteed emissions | 30 mg/Nm³ |
Source: Advanced Cyclone Systems (ACS) case study. Figures and photos: ACS.