The problem
The spray dryer manufacturer’s cyclone reached 83% efficiency, so 17% of a very valuable powder went to the bag filter. Under GMP, only powder recovered in the cyclone counts as product; powder in the bag filter cannot be recovered.
The solution
Hovione supplied the particle size distribution, the key input for an accurate efficiency guarantee. Using its PACyc (Particle Agglomeration in Cyclones) model, ACS designed a Hurricane cyclone ø530 mm for 1500 kg/h at 85 °C and guaranteed powder losses of 2–4%.




| Powder | Active pharmaceutical ingredient (API) |
|---|---|
| Design flow rate | 1500 kg/h N₂ + 40 kg/h H₂O |
| Temperature | 85 °C |
| Median particle size | 5.5 µm |
| Material in contact | AISI 316L |
Result
Hovione reported a global efficiency of 96–98%, in line with the PACyc model. The €50 k investment paid back almost immediately, and Hovione has since bought cyclones for 14 more spray dryers.
| Existing cyclone efficiency | 83 % |
|---|---|
| Guaranteed efficiency | > 96 % |
| Verified efficiency | 96–98 % |
| Powder losses | 17 % → 2–4 % |
| Investment | €50 k, almost immediate payback |
Source: Advanced Cyclone Systems (ACS) case study. Figures and photos: ACS.