The problem
The existing cyclone on the flash drying line lost more than 9% of the product, and the losses overloaded the wet scrubber downstream.
The solution
Samples were analysed in Porto for particle size and apparent density, and trial runs on ACS’s pilot unit with the client’s product confirmed the projection. The Hurricane RE was optimized for today’s flow and the higher flow planned after a dryer upgrade.
The system is four Hurricane RE ø1450 mm cyclones in parallel discharging through rotary airlocks to a common hopper, in stainless steel AISI 316L with food‑grade finish, pressure detectors, explosion suppression, CIP nozzles and clad insulation.



| Powder | Fish and seafood flavours |
|---|---|
| Actual flow rate | 16 800 m³/h |
| Temperature | 80 °C |
| Inlet concentration (dry) | 9 587 mg/Nm³ |
Result
Firmenich confirmed after testing that yield improved across the board, with an average increase of 10%. Other Firmenich plants are now being reviewed for the same technology.
| Existing losses | > 9 % |
|---|---|
| Predicted efficiency, Hurricane | 98.1–99.7 % |
| Expected pressure drop | 1.3 kPa |
| Verified yield increase | ≈ 10 % |
Source: Advanced Cyclone Systems (ACS) case study. Figures and photos: ACS.