The problem
The bubbling fluidized bed boiler burns coal or palm shell. Near a major tourist resort, air quality had to be kept high, and Indonesian regulation set a limit of 150 mg/Nm³ for particulates.
The solution
The customer provided the flue gas conditions and a dust sample from a bag filter at a similar plant, which set the particle size distribution. ACS installed a ReCyclone MH of four Hurricane cyclones and four mechanical recirculators after a pre‑separator, for 6972 m³/h at 230 °C.

| Fuel | Coal or palm shell |
|---|---|
| Boiler | Bubbling fluidized bed (BFB) |
| Actual flow rate | 6 972 m³/h |
| Temperature | 230 °C |
| Inlet concentration | 5 600 mg/Nm³ |
Result
The system reduces dust from 5600 mg/Nm³ to below 150 mg/Nm³ at 2.0 kPa, about 98%, and smoke at the stack is not visible. Investment is lower than an electrostatic precipitator, and maintenance and operating costs are lower than a bag filter.
| Guaranteed emissions, coal | 150 mg/Nm³ |
|---|---|
| Guaranteed emissions, palm shell | 100 mg/Nm³ |
| Expected emissions, palm shell | 80 mg/Nm³ |
| Pressure drop | 2.0 kPa |
| Dust reduction | ≈ 98 % |
Source: Advanced Cyclone Systems (ACS) case study. Figures and photos: ACS.