The problem
Fines escaping the dryer’s five process cyclones went to a wet scrubber. For premium whey powder used in infant nutrition, the scrubber was a hygiene risk, and a bag filter could not collect first‑grade product because of fibre and cross‑contamination.
The solution
ACS joined the main line and the vibrofluidizer line into one duct feeding four new Hurricane RE ø2900 mm agglomerator cyclones. It replaced two fans, added a new one for the system pressure drop, and installed the whole project on site.



| Powder | Demineralized whey powder |
|---|---|
| Actual flow rate | 98 317 m³/h (wet) |
| Temperature | 65 °C |
| Inlet concentration (dry) | 200 mg/Nm³ |
Result
Expected emissions are 20 mg/Nm³ (guaranteed 30 mg/Nm³), with the recovered powder kept as premium product. Eurosérum is now looking at a similar installation for a nearby plant.
| Expected emissions | 20 mg/Nm³ |
|---|---|
| Guaranteed emissions | 30 mg/Nm³ |
| Wet scrubber | Removed from the line |
Source: Advanced Cyclone Systems (ACS) case study. Figures and photos: ACS.